SMART BILGE 15PPM OIL CONTENT MONITOR
The RIVERTRACE SMART BILGE 15ppm Oil Content Monitor was developed in 2005 to meet and exceed the requirements for MEPC.107(49) regulations.
The SMART BILGE is made up of 2 key components, the SMART BILGE ‘Module’ and the SMART ‘CELL’ measuring cell. The SMART CELL utilises a unique Detector Array Technology, developed by Rivertrace, allowing the OCM to analyse all three oil types (HFO, Diesel and Emulsions) simultaneously without the need for re-calibration. This innovative design allows for simple routine maintenance of the OCM while maintaining optimal conditions.
Optical cell fouling is recognised as a leading cause of monitor malfunction or incorrect reading. A manual cell cleaning device is included as standard to easily enable routine maintenance.
Replacement calibrated measuring cells can be purchased for easy change over on board the vessel and calibration check kits enable the crew to demonstrate the monitor is within factory calibration to PSC Surveyors.
| MEASUREMENT | |
| Oil types : | HFO, Diesel and Mixture C (IMO defined) |
| Clean water calibration : | +/- 2ppm of factory set values |
| Oil range : | 0 – 40 ppm |
| Accuracy oil + solids : | +/- 5ppm up to 30 ppm |
| Solids discrimination : | 100ppm Iron Oxide in 10 ppm Diesel |
| Response time : | < 5 sec (oil reading) |
| ALARMS | |
| Oil alarm 1 setpoint : | 1 – 15 ppm user adjustable |
| Oil alarm 2 setpoint : | 1 – 15 ppm user adjustable |
| Oil alarm 1 delay : | 0 – 5 seconds user adjustable |
| Oil alarm 2 delay : | 0 – 600 seconds user adjustable |
| INPUT / OUTPUT | |
| Analogue output : | Active 4-20mA / 0 – 20mA |
| Switch inputs : | 2 x switch inputs for separator and backflush status |
| DATA STORAGE AND RETRIEVAL | |
| Calibrate on data storage : | Stored in cell |
| IMO required data : | Stored in Control enclosure |
| IMO required data retrieval : | Via LCD display, RS 232 comms link or USB |
| SYSTEM AND SUPPLY | |
| Supply voltage : | 115 or 230V AC, 50 – 60Hz (24V AC & 12V DC available) |
| Supply voltage Consumption : | < 50 VA incl. solenoid valve |
| Supply voltage tolerance : | +/- 15% |
| Projected life : | > 50,000 hrs |
| Protection class : | IP 65 |
| Approvals : | MEPC 107(49) – DNV-GL, USCG, CCS, , Russian Register, Transport Canada. |
| Weight : | 3.2 Kg / 7.05lb |
5PPM Alarm – The Smart Cell Bilge Alarm is readily available as a 5ppm version if required.
Autoclean – our pneumatic autoclean solution has been designed to ensure the measuring cell glass tube his kept free from fouling. Cell fouling is recognised as a leading cause of monitor malfunction. Fitting the autoclean removed the need for the ship’s crew to remember to clean the cell manually.
Flowswitch – The flowswitch option has been designed to ensure that bilge water is flowing through the measuring cell when in monitoring mode. An error is shown on the display if there is no flow. The flowswitch monitors the flow of water through the cell. This ensures that the flow cannot be shut off accidentally or maliciously. In case of no flow, the Smart Bilge will close the overboard discharge valve.
Hazardous Environments (Zone 1 & 2) – The SMART BILGE can be offered in an explosion proof cabinet.
All options can be ordered from new or retrofitted to existing Rivertrace Smart Bilge monitors.
Read more :
Source: rivertrace.com
Wireless position sensor GNOM DP S7 is used in transport telematics systems (GPS/GLONASS vehicle monitoring…
Pressure sensor GNOM DDE is used to determine the axle load in vehicles equipped with…
Axle Load Sensor GNOM DP Technoton position sensor is designed for measuring axle and cargo…
FMSCrocodile is used within for vehicle telematics system as a ready-made solution for safe integration…
Contactless J1708 Reader Technoton is designed for safe data reading from J1708 bus (SAE J1587)…
CANCrocoLITE Technoton — is a tool for Telematics systems used for data reading from on-board…
This website uses cookies.
View Comments