RIVERTRACE SMART ESM
In January 2020, the IMO 2020 global sulphur cap came into force to improve air quality, preserve the environment and protect human health. RIVERTRACE Smart ESM – Scrubber Washwater Monitor to comply with this sulphur reduction a popular solution is to install an exhaust gas cleaning system (EGCS).
For this, wet scrubber systems use wash water to remove the pollutants from the exhaust gas. Therefore the wash water being discharged must be monitored at all times to ensure it is within the limits set by the regulating body. There are IMO regulations for water quality parameters including Polycyclic Aromatic Hydrocarbons (PAHs), pH and turbidity prior to discharge into the ocean.
With over 35 years experience designing equipment for the marine environments, Rivertrace has developed our SMART ESM. The SMART ESM designed to MEPC.259(68) and is suitable for both the inlet and outlet of a EGCS, measuring and recording the required parameters of PAH, Turbidity, Temperature and pH. The monitor can be installed on new build of retrofit systems and can accommodate open-loop, closed-loop and hybrid scrubber systems.
The innovative measuring cell design allows for unique Plug and play maintenance design. Each measurement parameter is enclosed in a separate cassette slotted inside the measuring cell around the sample tube. This allows the calibrated parts to be swapped without the need of isolating the sample which flows through a glass tube in the centre of the cell.
| PAH Range | 0?g/L to 4500?g/L |
| PAH Accuracy | 5% of measurement reading |
| PaH Measurement Principle | UV Fluorescence |
| Turbidity Range | 0 – 500 NTU |
| Turbidity Accuracy | 0.1NTU up to 100 NTU, 1NTU thereafter. |
| Turbidity Measurement Principle | IR Scattering |
| pH Range | 0 – 14 pH |
| pH Accuracy | 0.1 pH |
| pH Measurement Principle | pH Electrode |
| Sample / Clean Water Temperature range | 0oC to 40oC* |
| *Higher optional with Heat Exchanger | |
| Sample / Clean Water pressure range | 1 to 9 Bar |
| Optimum Measuring pressure (Sample / Clean) | 3 Bar |
| Required Air Supply Pressure Range | 4 – 6 Bar |
| Compressed Air normal / average consumption | 450mL / Hr |
| Sample / Clean Water Flow rate range | 1 to 4 LPM |
| Ambient Temperature range | 0°C to 50°C |
| Supply Voltage | 230 VAC 50/60 Hz |
| Outputs | MODBUS |
| 4-20mA | |
| Response Time | 266 seconds at 1l/m flow rate |
| Storage | Internal SD Card |
| Downloadable to External USB | |
| IP Rating | IP66 |
| Wetted Parts Material | uPVC, Nylon, Black acetal copolymer and peek |
| Approvals | DNV Type Approval |
At Rivertrace we understand every EGCS is different, and we can tailor our system to accommodate the specific parameters and requirements for the scrubber and vessel.
We offer 2 main designs for our equipment which can be customised further with additional components based on technical requests.
Option 1 – Frame Mounted. This option is based on a modular design all mounted onto a frame / backplate. It consists of a cooled cabinet housing the Control Module and Measuring Cell with a separate enclosure for the electronics.
Option 2 – Box Mounted. This option is based on a twin enclosure design.
It consists of a cooled cabinet housing the Control Module and electronics and a separate compartment for the Measuring Cell and sample conditioning equipment.
Other optional components include :
Read more :
Source: rivertrace.com
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.
View Comments