Inameq

Fluidwell Indicator Liquid Type F116 Series For Ship Application
Fluidwell Indicator Liquid Type F116 Series For Ship Application

Fluidwell Indicator Liquid Type F116 Series For Ship

1
3 minutes, 25 seconds Read

Intrinsically Safe – Differential / Sum Flow Computer with analog and pulse outputs

Product description

The F116 flow computer has been developed to calculate differential / consumption or total volume. The usual difficulties encountered in such applications include : pulsating flows, very low consumption readings, vibration and high ambient temperatures. These are all well catered for in the design and operation of the F116. The pulse and analog outputs do reflect the calculated differential or sum value.

Fluidwell Indicator Liquid Type F116 Series For Ship Application
Fluidwell Indicator Liquid Type F116 Series For Ship Application

The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available – ATEX and IECEx approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Features

  • Calculates differential flow rate (consumption), total and accumulated total of flow A and B.
  • Calculates the sum flow rate, total and accumulated total of flow A and B.
  • Precautions for pulsating flows and very low consumption readings.
  • Analog and pulse outputs.
  • Displays total and flow rate simultaneously.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67″) or 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Separate engineering units for flow rate and total on the display.
  • LED backlight.
  • Intrinsically safe according ATEX and IECEx.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.
Fluidwell Indicator Liquid Type F116 Series For Input And Output
Fluidwell Indicator Liquid Type F116 Series For Input And Output

Applications

  • Differential function : fuel consumption calculation for diesel engines on board of ships or locomotives.
  • Sum function: where flows are split-up in two pipe-lines and total flow has to be calculated.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
    Different pulse signal types are allowed for input A and B.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to differential or sum accumulated total (e.g. a pulse every 3.25 gallons).
    Max. frequency: 500Hz.
    Adjustable pulse length from 0.001 sec. to 9.999 seconds. The directional output is switched as soon as the pulse output reflects a “negative” differential.
  • Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Alarm outputs None
Analog outputs
  • Function: Re-transmitting the differential or totalized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA Output loop-powered.
  • 8 – 24V AC/DC.
  • 115 – 230V AC.
  • Basic: 8 – 30V DC.
Sensor Supply
  • 3.2, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • ATEX:
    Gas: II 1 G Ex ia IIB/IIC T4 Ga
    Dust: II 1 D Ex ia IIIC T100 °C Da
  • IECEx:
    Gas: Ex ia IIC/IIB T4 Ga
    Dust: Ex ia IIIC T100 °C Da
Explosion Proof
  • ATEX: 
    Gas: II 2 G / Ex d IIB T5 Gb
    Dust: II 2 D / Ex t IIIB T100°C Db

 

Communication
Communication
  • Function: All process data and settings can be read and modified through the communication link.
  • Protocol: Modbus RTU.
  • Interface: RS232 / RS485 2-wire or 4-wire / TTL.
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Fluidwell Indicator Liquid Type F116 Series Indicator
Fluidwell Indicator Liquid Type F116 Series Indicator

Read more : Fluidwell Indicator Liquid Type F190 Series For Ship

author

Indonesia Marine Equipment

INAMEQ is provide all marine product (equipment and sparepart) and news about marine product to help procurement team at shipping industry, ship contractor, port contractor and oil gas company finding competitive price to directly connect with manufacturer and authorized local and international.

Similar Posts

Comments

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Discover more from Inameq

Subscribe now to keep reading and get access to the full archive.

Continue reading