The robust Flowmeter Fluidwell Type E126-EG Series For Offshore is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions.

Flowmeter Fluidwell Type E126-EG Series For Offshore Application
Flowmeter Fluidwell Type E126-EG Series For Offshore Application

The E126-EG measures the actual flow, temperature and pressure and converts it with an ideal gas formula to gas volume at reference conditions (e.g. 0°C/1.013Bar or 14.7PSI /60°F). The reference conditions can be configured in the settings. A compressibility factor can be set to approach a real gas behaviour.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E126-EG Series For Offshore
Flowmeter Fluidwell Type E126-EG Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett gas flow calculation at base conditions is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E126-EG Series For Offshore Input
Flowmeter Fluidwell Type E126-EG Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Temperature Inputs
  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.
Pressure Inputs
  • (0)4 – 20mA. Contact us for latest specifications.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information and reading / writing all configuration settings.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

Flowmeter Fluidwell Type E126-EG Series For Offshore Indication

Flowmeter Fluidwell Type E126-EG Series For Offshore Indication
Flowmeter Fluidwell Type E126-EG Series For Offshore Indication

Read more : Flowmeter Fluidwell Type E126-EL Series For Offshore

Flowmeter Fluidwell Type E126-EG Series For Offshore

Explosion proof – Flowcomputer

with temperature and pressure compensation for corrected gas volume

Product description

The robust Flowmeter Fluidwell Type E126-EG Series For Offshore is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions.

Flowmeter Fluidwell Type E126-EG Series For Offshore Application
Flowmeter Fluidwell Type E126-EG Series For Offshore Application

The E126-EG measures the actual flow, temperature and pressure and converts it with an ideal gas formula to gas volume at reference conditions (e.g. 0°C/1.013Bar or 14.7PSI /60°F). The reference conditions can be configured in the settings. A compressibility factor can be set to approach a real gas behaviour.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E126-EG Series For Offshore
Flowmeter Fluidwell Type E126-EG Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett gas flow calculation at base conditions is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E126-EG Series For Offshore Input
Flowmeter Fluidwell Type E126-EG Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Temperature Inputs
  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.
Pressure Inputs
  • (0)4 – 20mA. Contact us for latest specifications.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information and reading / writing all configuration settings.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

Flowmeter Fluidwell Type E126-EG Series For Offshore Indication

Flowmeter Fluidwell Type E126-EG Series For Offshore Indication
Flowmeter Fluidwell Type E126-EG Series For Offshore Indication

Read more : Flowmeter Fluidwell Type E126-EL Series For Offshore

Fluidwell E126-EL Series Flowmeter For Offshore Application

Explosion proof – Flowcomputer

with temperature compensation for corrected liquid volume

Product description

The robust Flowmeter Fluidwell Type E126-EL Series For Offshore is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions.

Flowmeter Fluidwell Type E126-EL Series For Offshore Application
Flowmeter Fluidwell Type E126-EL Series For Offshore Application

The corrected volumetric flow is calculated by using the thermal expansion coefficient algorithm stored in the flowcomputer. The reference temperature can be defined as desired, e.g. 15°C, 20°C or 60°F.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E126-EL Series For Offshore
Flowmeter Fluidwell Type E126-EL Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, pressure, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett flow calculation at base conditions is desired without the influence of thermal product expansion.
  • A typical application is flow calculation of water, fuel or chemicals at base conditions.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E126-EL Series For Offshore Input
Flowmeter Fluidwell Type E126-EL Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Temperature Inputs
  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total and reading / writing all configuration settings.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator

Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator
Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E115 Series For Offshore

Flowmeter Fluidwell Type E126-EL Series For Offshore

Explosion proof – Flowcomputer

with temperature compensation for corrected liquid volume

Product description

The robust Flowmeter Fluidwell Type E126-EL Series For Offshore is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions.

Flowmeter Fluidwell Type E126-EL Series For Offshore Application
Flowmeter Fluidwell Type E126-EL Series For Offshore Application

The corrected volumetric flow is calculated by using the thermal expansion coefficient algorithm stored in the flowcomputer. The reference temperature can be defined as desired, e.g. 15°C, 20°C or 60°F.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E126-EL Series For Offshore
Flowmeter Fluidwell Type E126-EL Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, pressure, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett flow calculation at base conditions is desired without the influence of thermal product expansion.
  • A typical application is flow calculation of water, fuel or chemicals at base conditions.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E126-EL Series For Offshore Input
Flowmeter Fluidwell Type E126-EL Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Temperature Inputs
  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total and reading / writing all configuration settings.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator

Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator
Flowmeter Fluidwell Type E126-EL Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E115 Series For Offshore

Fluidwell E115 Series Flowmeter For Offshore Application

Explosion proof – Bi-directional Flow rate Indicator / Totalizer

with analog, pulse and flow direction outputs

Product description

Fluidwell E115 Series Flowmeter For Offshore Application has been developed for applications where the direction of flow is an issue. Applications can be found by loading and unloading of ships where one bi-directional flowmeter is used. Another application is the correction of back-flow due to shocks in a pipeline caused by piston pumps or valve behavior. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase.

Flowmeter Fluidwell Type E115 Series For Offshore Application
Flowmeter Fluidwell Type E115 Series For Offshore Application

The E-series distinguishes itself by its quality and functionality driven European design and manufacturing. It is more than fulfilling the rules for explosion proof design, it is about safety during the daily operation. Often, the environment is much tougher than the explosion proof requirements demand. Thus dangerous conditions may be experienced due to a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E115 Series For Offshore
Flowmeter Fluidwell Type E115 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Detects flow direction with quadrature signal inputs.
  • Key information at a glance as the display shows forward & reverse flow rate, forward & reverse total, accumulated total count up and count down ref. flow direction, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • For bi-directional flow measurement applications like loading / unloading (of ships) through the same flowmeter.
  • When undesired backflow (due to shocks in a pipeline caused by piston pumps or valve behavior) disturbs a correct totalization.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E115 Series For Offshore Input
Flowmeter Fluidwell Type E115 Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function:Scaled pulse output according to the bi-directional accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: Up to two passive NPN transistors and up to two isolated electro-mechanical relays.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the forward, reverse or differential flow rate. – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type : RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool.
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E115 Series For Offshore Indicator
Flowmeter Fluidwell Type E115 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E112 Series For Offshore

Flowmeter Fluidwell Type E115 Series For Offshore

Explosion proof – Bi-directional Flow rate Indicator / Totalizer

with analog, pulse and flow direction outputs

Product description

Flowmeter Fluidwell Type E115 Series For Offshore has been developed for applications where the direction of flow is an issue. Applications can be found by loading and unloading of ships where one bi-directional flowmeter is used. Another application is the correction of back-flow due to shocks in a pipeline caused by piston pumps or valve behavior. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase.

Flowmeter Fluidwell Type E115 Series For Offshore Application
Flowmeter Fluidwell Type E115 Series For Offshore Application

The E-series distinguishes itself by its quality and functionality driven European design and manufacturing. It is more than fulfilling the rules for explosion proof design, it is about safety during the daily operation. Often, the environment is much tougher than the explosion proof requirements demand. Thus dangerous conditions may be experienced due to a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E115 Series For Offshore
Flowmeter Fluidwell Type E115 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Detects flow direction with quadrature signal inputs.
  • Key information at a glance as the display shows forward & reverse flow rate, forward & reverse total, accumulated total count up and count down ref. flow direction, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • For bi-directional flow measurement applications like loading / unloading (of ships) through the same flowmeter.
  • When undesired backflow (due to shocks in a pipeline caused by piston pumps or valve behavior) disturbs a correct totalization.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E115 Series For Offshore Input
Flowmeter Fluidwell Type E115 Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function:Scaled pulse output according to the bi-directional accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: Up to two passive NPN transistors and up to two isolated electro-mechanical relays.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the forward, reverse or differential flow rate. – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type : RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool.
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E115 Series For Offshore Indicator
Flowmeter Fluidwell Type E115 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E112 Series For Offshore

Fluidwell E112 Series Flowmeter For Offshore Application

Explosion proof – Flow rate Indicator / Totalizer

with linearization, analog and pulse outputs

Product description

The E112 is a popular model in our range of explosion proof flow rate indicators / transmitters. In addition to the average K-Factor, 15 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation.

Flowmeter Fluidwell Type E112 Series For Offshore Application
Flowmeter Fluidwell Type E112 Series For Offshore Application

Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven Explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E112 Series For Offshore
Flowmeter Fluidwell Type E112 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, measuring units and a flow rate indicating speedometer.
  • 15 point linearization of the flow curve – with interpolation.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Data logging of flow rate, total and accumulated total. Learn more with this interactive tutorial.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement with mechanical flowmeters where a precise calculation over the full measurement range is required.
  • If re-transmission of the flow rate and/or totalizer functions or serial communication is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E112 Series For Offshore Input
Flowmeter Fluidwell Type E112 Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA. Contact us for latest specifications.
  • 0 – 10V DC. Contact us for latest specifications.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons). and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E112 Series For Offshore Indicator
Flowmeter Fluidwell Type E112 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E110 Series For Offshore

Flowmeter Fluidwell Type E112 Series For Offshore

Explosion proof – Flow rate Indicator / Totalizer

with linearization, analog and pulse outputs

Product description

The E112 is a popular model in our range of explosion proof flow rate indicators / transmitters. In addition to the average K-Factor, 15 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation.

Flowmeter Fluidwell Type E112 Series For Offshore Application
Flowmeter Fluidwell Type E112 Series For Offshore Application

Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven Explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E112 Series For Offshore
Flowmeter Fluidwell Type E112 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, measuring units and a flow rate indicating speedometer.
  • 15 point linearization of the flow curve – with interpolation.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Data logging of flow rate, total and accumulated total. Learn more with this interactive tutorial.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement with mechanical flowmeters where a precise calculation over the full measurement range is required.
  • If re-transmission of the flow rate and/or totalizer functions or serial communication is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.
Flowmeter Fluidwell Type E112 Series For Offshore Input
Flowmeter Fluidwell Type E112 Series For Offshore Input

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA. Contact us for latest specifications.
  • 0 – 10V DC. Contact us for latest specifications.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons). and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E112 Series For Offshore Indicator
Flowmeter Fluidwell Type E112 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E110 Series For Offshore

Fluidwell E110 Series Flowmeter For Offshore Application

Explosion proof – Flow rate Indicator / Totalizer

with analog and pulse signal outputs

Product description

The Flowmeter Fluidwell Type E110 Series For Offshore is a popular model in our range of explosion proof flow rate indicators / transmitters, complete with pulse and analog output signals. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation.

Flowmeter Fluidwell Type E110 Series For Offshore Application
Flowmeter Fluidwell Type E110 Series For Offshore Application

Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E110 Series For Offshore
Flowmeter Fluidwell Type E110 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Data logging of flow rate, total and accumulated total. Learn more with this interactive tutorial.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.
Flowmeter Fluidwell Type E110 Series For Offshore Input
Flowmeter Fluidwell Type E110 Series For Offshore Input

Applications

  • Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA. Contact us for latest specifications.
  • 0 – 10V DC. Contact us for latest specifications.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons). and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E110 Series For Offshore Indicator
Flowmeter Fluidwell Type E110 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E018 Series For Offshore

Flowmeter Fluidwell Type E110 Series For Offshore

Explosion proof – Flow rate Indicator / Totalizer

with analog and pulse signal outputs

Product description

The Flowmeter Fluidwell Type E110 Series For Offshore is a popular model in our range of explosion proof flow rate indicators / transmitters, complete with pulse and analog output signals. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation.

Flowmeter Fluidwell Type E110 Series For Offshore Application
Flowmeter Fluidwell Type E110 Series For Offshore Application

Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.

Features

Flowmeter Fluidwell Type E110 Series For Offshore
Flowmeter Fluidwell Type E110 Series For Offshore
  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Data logging of flow rate, total and accumulated total. Learn more with this interactive tutorial.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Advantages

  • Saves time and improves flexibility with the through-glass keypad: no need to open the front cover.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Durable high-grade stainless steel 316L Ex d enclosure withstanding extreme (maritime) conditions.
Flowmeter Fluidwell Type E110 Series For Offshore Input
Flowmeter Fluidwell Type E110 Series For Offshore Input

Applications

  • Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.

Product specifications

Signal Input
Flowmeters Inputs
  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA. Contact us for latest specifications.
  • 0 – 10V DC. Contact us for latest specifications.
Status Inputs
  • Remote control: external input for clearing total or to disable manual clearing by the keypad.

 

Signal Output
Pulse outputs
  • Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons). and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type: One passive NPN transistor and one isolated electro-mechanical relay.
Alarm outputs
  • None
Analog outputs
  • Function: Re-transmitting the flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One galvanically isolated, loop powered 4 – 20mA output.

 

Supply
Power Supply
  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.
Sensor Supply
  • 3, 8.2, 12, 24V DC.

 

Hazardous Area
Intrinsically Safe
  • For Intrinsically Safe applications we recommend the F-Series.
Explosion Proof
  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

 

Communication
Communication
  • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
  • Type: RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
Flowmeter Fluidwell Type E110 Series For Offshore Indicator
Flowmeter Fluidwell Type E110 Series For Offshore Indicator

Read more : Flowmeter Fluidwell Type E018 Series For Offshore