Inameq

Smart Turbidity For Marine
Smart Turbidity For Marine

Smart Turbidity For Marine

By utilising the “Smart Cell” Detector Array Technology, developed by Rivertrace, the monitor accurately analyses the quality of the sample stream and outputs the turbidity value in nephelometer turbidity units (NTU) Turbidity is the cloudiness or haziness of a fluid caused by large numbers of individual particles. A manual cell cleaning device is included as standard to easily enable routine maintenance and prevent Optical cell fouling which is recognised as a leading cause of monitor malfunction or incorrect reading. By simple operation of the manual cleaning device, the measuring cell remains in optimum operating condition.

Replacement calibrated measuring cells can be purchased for easy change over and calibration verification kits enable the user to demonstrate the monitor is within factory calibration.

Smart Turbidity For Marine
Smart Turbidity For Marine

The Smart Turbidity Monitor is also available for Hazardous area Environments classified as Zone 1 & 2.

The Smart Cell Bilge Alarm is readily available as a 5ppm version if required. It can also be tailor made for Hazardous Environments (Zone 1 & 2) as an Exd system with Auto Clean, all enclosed in an explosion proof cabinet.

APPLICATIONS

  • Sewage Treatment Plant Effluent Monitor.
  • Brewing Quality Monitor.
  • Groundwater Effluent.

OPTIONS

All options can be ordered from new or retrofitted to existing Rivertrace Smart Cell monitors.

AUTOCLEAN

The autoclean option has been designed to ensure that the measuring cell glass tube is kept free from fouling. Cell fouling is recognised as a leading cause of monitor malfunction. Fitting the Autoclean removes the need for the ship’s crew to remember to clean the cell manually.

AUTOCLEAN
AUTOCLEAN

CALIBRATION CHECK

The monitor’s calibration can be checked using our calibration check kit. This is an approved method of demonstrating that the unit is still working correctly.

CALIBRATION CHECK
CALIBRATION CHECK

SPECIFICATION

MEASUREMENT
Clean water calibration: +/- 2ppm of factory set values
Turbidity range: 0 – 100 NTU
Accuracy: +/- 1 NTU
Response time: < 5 sec
ALARMS
Alarm 1 set point: 1 – 100 NTU user adjustable
Alarm 2 set point: 1 – 100 NTU user adjustable
Alarm 1 delay: 0 – 5 seconds user adjustable
Alarm 2 delay: 0 – 600 seconds user adjustable
INPUT / OUTPUT
Analogue output: Active 4-20mA / 0 – 20mA
DATA STORAGE AND RETRIEVAL
Calibrate on data storage: Stored in cell assembly
SYSTEM AND SUPPLY
Supply voltage: 115 or 230V AC, 50 – 60Hz (24V AC & 12V DC available)
Supply voltage Consumption: < 50 VA
Supply voltage tolerance: +/- 15%
Projected life: > 50,000 hrs
Protection class: IP 65
Weight: 3.2 Kg / 7.05lb

Specifications and system descriptions accurate at time of printing. These are subject to change.

Read more SMARTSAFE ORB (Oil Record Book); SMART BILGE 15PPM OIL CONTENT MONITOR; SMART PFM 107 OIL IN WATER MONITOR; SMART ODME FOR MARINE; SMART ESM – Exhaust Scrubber Washwater Monitor; OCD 50M OIL IN WATER MONITOR; OCD CW COOLING WATER MONITOR

author

Indonesia Marine Equipment

INAMEQ is provide all marine product (equipment and sparepart) and news about marine product to help procurement team at shipping industry, ship contractor, port contractor and oil gas company finding competitive price to directly connect with manufacturer and authorized local and international.

Similar Posts

2 Comments

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.