Universal device for manifold application needs. Due to their continuous ongoing development, the highly modular OMG series covers a broad range of applications. KRAL Flowmeters OMG Series is therefore particularly suitable for manifold applications, such as mechanical engineering, chemical engineering, and marine.
The flow meters OMG series also combines robustness with the highest precision, characteristics for which KRAL flow meters are well-known worldwide. Due to the screw pump principle, all OMG series devices are very smooth-running and fast and can follow quick, pulsation-related changes in flow rates. Due to their extremely robust construction, the OMG series provides optimal protection against external influences, such as system vibrations and mechanical stresses in harsh environments.
| Technical data | OMG-13 | OMG-20 | OMG-32 | OMG-52 | OMG-68 | OMG-100 | OMG-140 | |
|---|---|---|---|---|---|---|---|---|
| Nominal diameter | DN [mm] | 15 | 20 | 25/32 | 40 | 50 | 100 | 150 |
| DN [inch] | 1/2 | 3/4 | 1 | 1 1/2 | 2 | 4 | 6 | |
| Total length with DIN flange | [mm] | 145 | 185 | 255/265 | 285 | 340 | 460 | 610 |
| Weight with DIN flange | [Kg] | 6 | 6 | 13/15 | 21 | 31 | 77 | 190 |
| Flow rate I/h | Qmax | 900 | 2,700 | 9,000 | 31,500 | 63,000 | 180,000 | 450,000 |
| Qnom | 600 | 1,800 | 6,000 | 21,000 | 42,000 | 120,000 | 300,000 | |
| Qmin | 6 | 18 | 60 | 210 | 420 | 1,200 | 3,000 | |
| Flow rate I/min | Qmax | 15 | 45 | 150 | 525 | 1,050 | 3,000 | 7,500 |
| Qnom | 10 | 30 | 100 | 350 | 700 | 2,000 | 5,000 | |
| Qnom | 0.1 | 0.3 | 1.0 | 3.5 | 7.0 | 20 | 50 | |
| Max. pressure | [bar] | 250 | 250 | 250 | 160 | 100 | 40 | 40 |
| Temperature | [°C] | -20 to +200 | -20 to +200 | -20 to +200 | -20 to +200 | -20 to +200 | -20 to +200 | -20 to +200 |
| Viscosity | [mm²/s] | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 | 1 to 1×106 |
| Precision | measurement of value | ±0.1 % | ±0.1 % | ±0.1 % | ±0.1 % | ±0.1 % | ±0.1 % | ±0.1 % |
| Repeatability | ±0.01 % | ±0.01 % | ±0.01 % | ±0.01 % | ±0.01 % | ±0.01 % | ±0.01 % | |
| K-factor | K1 [P/I] | 1,216 | 640 | 234 | 71.0 | 39.8 | 16.8 | 8.8 |
| K2 [P/I] | 2,432 | 1,280 | 468 | 142 | 79.6 | 33.6 | 17.7 | |
| K3 [P/I] | 7,296 | 2,560 | 1,014 | 302 | 167 | 57.6 | 22.1 | |
| K4 [P/I] | 7,296 | 2,560 | 1,014 | 302 | 167 | 87.6 | 45.1 | |
| Frequency | f1 at Qnom [Hz] | 203 | 320 | 390 | 414 | 464 | 560 | 738 |
| f2 at Qnom [Hz] | 405 | 640 | 780 | 828 | 929 | 1,120 | 1,475 | |
| f3 at Qnom [Hz] | 1,216 | 1,280 | 1,690 | 1,760 | 1,949 | 1,920 | 1,842 | |
| f4 at Qnom [Hz] | 1,216 | 1,280 | 1,690 | 1,762 | 1,948 | 2,920 | 3,758 | |
| Sensor | BEG 06* / BEG 06A* | BEG 43D | BEG 44A | BEG 45 with BEV 13 | BEG 47D** / BEG 47E** | BEG 53A* / BEG 54A* | |
|---|---|---|---|---|---|---|---|
| Application | Ex-range | Standard | High pressure | High pressure, wide temperature range | Ex-range | Flow direction detection | |
| K-factor | K1 | K1 | K2 | K3 | K1 | K4 | |
| Signal | Namur | PNP | PNP | PNP | Namur | Push-Pull | |
| Temperature | [°C] | -40 bis +150 | -40 to +150 | -40 to +150 | -40 to +250 | -25 (-40) to +150 | -40 to +150 |
| Max. pressure | [bar] | 350 | 250 | 420 | 420 | 40 | 650 |
| *dependent on nominal diameter | **dependent on temperature | ||||||
Read More Articles:
Reference: kral.at
Wireless position sensor GNOM DP S7 is used in transport telematics systems (GPS/GLONASS vehicle monitoring…
Pressure sensor GNOM DDE is used to determine the axle load in vehicles equipped with…
Axle Load Sensor GNOM DP Technoton position sensor is designed for measuring axle and cargo…