MIDAS BathyPack Bathymetry PackageMIDAS BathyPack Bathymetry Package
The BathyPack is one of Valeport’s premier MIDAS products, using state of the art sensors to generate precision Sound Velocity and Density profiles for highly accurate depth and height data.
The simple top-end PC software, BathyLog, also allows all profile data to be used to monitor and correct multiple miniIPS pressure sensors, giving you the complete picture with one integrated sensor suite.
Robust, accurate inductive cell. Digital sampling technique means no more field calibrations.
Range : | 0 – 80 mS/cm |
Accuracy : | ±0.01 mS/cm |
Resolution : | 0.002 mS/cm |
Type : | Fast Response PRT with guard |
Range : | -5 to +35 °C |
Accuracy : | ±0.005 °C |
Resolution : | 0.002 °C |
Revolutionary temperature compensated piezo-resistive sensor; all the performance of a resonant quartz sensor but with long term stability and better durability. No more oil!
Range : | 10, 30, 100, 300 or 600Bar |
Accuracy : | ±0.01% range |
Resolution : | 0.001% range |
Valeport’s digital time of flight sensor – the most accurate SV sensor in the world.
Range : | 1375 – 1900 m/s |
Accuracy : | ±0.02 m/s |
Resolution : | 0.001 m/s |
BathyPack accepts a variety of industry standard devices. Typical specification – Valeport VA500 Altimeter :
Frequency : | 500kHz |
Range : | 0 – 50 m (6000m depth rating) |
Resolution : | 1mm |
Density : | EOS-80 Equation of State of Seawater |
Salinity : | PSS78 Practical Salinity Scale |
Depth : | UNESCO Pressure/Depth Relationship or Simplified “Mean Density” Correction |
Data Sampling : | 2 Hz |
Lookup Table : | 6000 points (1m res. @ max depth) |
Sampling Sequence : | Synchronous |
The instrument will operate by direct communications with PC before and after deployment. It also operates in real time, with a choice of communication protocols for a variety of cable lengths, all fitted as standard and selected by pin choice on the output connector :
RS232 | Up to 200m cable, direct to serial port via USB adaptor |
RS485 | Up to 1000m cable, addressable half duplex comms |
Baud Rate : | 2400 – 115200 |
Protocol : | 8 data bits, 1 stop bit, No parity, No flow control |
External Power : | 12 – 30vDC |
Power : | Nominal 4W max |
Connector : | SubConn MCBH10F |
Materials : | Titanium housing, polyurethane, composite and polycarbonate sensor components |
Depth Rating : | 6000m (may be limited by pressure sensor) |
Instrument Size : | 88mmØ x 425mm long |
Weight : | 6 kg |
Shipping : | 74 x 35 x 27cm; 13kg |
System is supplied with BathyLog Windows based PC software, for instrument setup and data display. BathyLog is licence free.
0608002 | MIDAS BathyPack in titanium Supplied with : ? 3m interface lead ? 0.5m altimeter input pigtail ? BathyLog software ? Manual and transit case. |
Associated Products | |
0760001 | miniIPS Pressure Sensor |
0430003 | VA500 Altimeter |
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…