iMag Seametrics Magnetic Flow Meter

0
23
iMag Seametrics Magnetic Flow Meter
iMag Seametrics Magnetic Flow Meter

GENERAL INFORMATION

The iMAG-Series is the most economical flanged electromagnetic flow meter on the market. It is used in 3” to 12”pipe in municipal or industrial water, waste water, pump stations and packaged plant applications. The iMAG has no moving parts and electrodes are designed to discourage fouling. This magmeter requires no maintenance in applications where debris would impede mechanical meters. There are no parts to wear out. Minimal straight pipe requirements allow iMAG-Series meters to be used in piping configurations where there is little space between the meter and an elbow.

iMAG-Series flow meters are rated IP68 for applications where the meter may be under water up to a depth of 10 feet (3 meters) for prolonged periods of time. Rate and total indication are standard. Rate and total units and pulse output are settable via the front panel touch key pad by the user. The iMAG can be externally powered with 9-36 Vdc at 30 mA. The standard 20-foot (6 meter) cable also provides outputs for use with a variety of Seametrics and other displays and controls for remote reading, data logging and telemetry applications. 4-20mA passive current loop and high frequency outputs are optional. The iMAG 3600 remote display flowmeter can be supplied with an optional internal AC power supply.

Positioning the Meter. 

These flowmeters can be installed horizontally, vertically, and in any radial position. Using a check valve on the upstream side of the meter, and/or an air vent (vacuum relief valve) in the same, unobstructed run of pipe as the meter, is required in any installation where the meter may be exposed to suction when the system is not in normal operation. Suction can cause damage to the liner. Liner damage caused by suction, without the use of a check valve and/or air vent, may void the warranty. Straight Pipe Recommendations. As with most flow meters, the iMAG requires straight pipe before and after the meter for best accuracy. However, the ability of electromagnetic meters to average the flow across the entire pipe allows for shorter straight pipe recommendations than most mechanical meters

Full Pipe Recommendations. All magmeters require a method for determining that the pipe is empty, to prevent false reading. This meter is designed to indicate ‘EMPTY PIPE’ if one or more electrodes is exposed. For highest accuracy, install the meter so that the pipe will be full when there is flow. If air bubbles may be present in the pipe or sludge accumulation is an issue, rotate the meter by one flange hole to position the control housing at a 45˚ angle.

FEATURES

  • Easy set up.
  • Minimal straight pipe.
  • Mounted or remote rate & total.
  • Tamper-evident seal.
  • NSF-61 approved.
  • IP68 rated.

THE RIGHT METER FOR

  • Water & Waste Water Treatment.
  • Municipal.
  • Treatment plants.
  • Pump stations.
  • Packaged plants.
  • Filtration systems.

SPECIFICATIONS

Pipe Size3”,4”, 6”, 8”, 10”,12”
Flanges150 lb. ANSI pattern
Pressure150 psi (10.3 bar) working pressur
TemperatureOperating10˚ to 130˚ F (-12˚ to 54˚ C)
Storage-40˚ to 158˚ F (-40˚ to 70˚ C)
Accuracy+/- 1% of reading +/- 0.25% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/se
Low Flow Cutof0.5% of maximum flow rat
Materials Body (3” Only)Ductile cast iron, powder-coated w/NSF61 listed epoxy powde
      Body (4”-12”Welded steel, epoxy-coated
      Liner (3” OnlyNoryl®
       Liner (4”-12”)Santoprene/Polypropylen
      Electronics HousingDuctile cast iron, powder-coate
      Electrodes316 stainless stee
      O-ring (3” Only)EPDM
Display       Type128×64 dot-matrix LCD
      Digits5 Digit Rate
      UnitsRate Volume UnitsRate Time UnitsTotal Volume Units
Gallons

Liters

Cubic Feet

Cubic Meters

Million Gallons

Mega Liters

Imperial Gallons

Million Imperial Gallons

Second

Minute

Hour

Day

Gallons

Gallons x 1000

Million Gallons

Liters

Liters x 1000

Mega Liters

Cubic Meters

Cubic Meters x 1000

Cubic Feet

Cubic Feet x 1000

Imperial Gallons

Imperial Gallons x 1000

Million Imperial Gallons

PowerDC Power9-36 Vdc @ 250 mA max, 30 mA average
AC Power185-264Vac, 50/60Hz, 0.12A
Telemetry Output3.3V asynchronous receive and transmit (UART) signals, ASCII command-response protocol
Pulse Frequency OutputSignalCurrent sinking pulse, isolated, 36 Vdc at 10 mA max
Pulse RatesUser-settable volume units/pulse. Pulse width is one-half of pulse period, 200 pulses/sec max
  Options4-20mA Current LoopIsolated, passive, 6-36Vdc, +/- 0.1% of pulse/frequency output HART compliant2
Digital OutputIsolated, open collector, 36Vdc @ 10mA max., frequency output up to 10kHz
Relay OutputSolid state relay, normally open, non-polarized, 28Vac/40Vdc @ 0.5A max, 33Hz max
Serial Communications2Isolated, asynchronous serial RS485 or RS232, Modbus RTU protocol
CableControl CableSix-conductor water-blocked cable, polyurethane jacket, 20ft (6m) standard length for power, pulse

frequency or optional outputs. Optional lengths up to 100’ available

Remote Display Cable (iMAG 3600)33ft (10m) standard length may be shortened (by user in the field). Additional cable can be ordered and attached with the use of a junction box (purchased from a standard supplier) up to 100ft (30m) total
Conductivity>20 microSiemens/cm
Empty Pipe DetectionHardware/software, conductivity-based
Regulatory(EN 61326) pending, NSF-61
EnvironmentalIP68 to 10ft (3m) depth