cNODE® is a family of transponders for underwater acoustic positioning and data link, and operates with both HiPAP®, HPR and cPAP® transceivers. The cNODE® transponders operates with either the HiPAP® / HPR 400 channels and telemetry or with the new Cymbal acoustic protocol.
The cNODEMaxi 31 Exd transponders are made especially for operating in an explosive atmosphere.
Two models are available :
• cNODE Maxi 31-80V-90-Exd.
• cNODEMaxi 31-80V-Exd.
The cNODEMaxi 31 Exd transponders comply with the following standards :
• IEC/EX 60079-1:2007
• IEC 60079-0:2011
• IEC 60086-1
• EN 60079-0:2012

Technical specifications
Materials
Bolts and tube:……………………..Super Duplex stainless steel
Transducer, top end cap and bottom end cap:………Titanium grade 5
Performance specifications
Operation depth :………………………………………………..1000 m
Operating frequency :…………………………..21 kHz to 31 kHz
Communication principle :………………….Phase Shift Keying (Cymbal) and Frequency Shift Keying (FSK)
Transducer beam width :……………………………….80° at -3 dB
Frequency band :……………………….Medium frequency (MF)
Source level :……………………………………………………..198 dB
Receiver sensitivity :……………………………………………..85 dB
Weight and outline dimensions
cNODE Maxi 31-80V-90-Exd
Width :……………………………………………………………..164 mm
Height :…………………………………………………………….874 mm
Weight in air :…………………………………………………….35.5 kg
Weight in water :…………………………………………………..25 kg
cNODE Maxi 31-80V-Exd
Width :…………………………………………………………..139.5 mm
Height :…………………………………………………………….880 mm
Weight in air :…………………………………………………….35.5 kg
Weight in water :…………………………………………………..25 kg
Power specifications
Battery type :….Non-rechargeable Lithium metal, (Li/SOC2)
Operating voltage :………………………………….10 to 14.4 VDC
Battery output :………………………………………………14.4 VDC
Total battery energy content :……………………………….128 Ah
Cells per battery :……………………………………………………….48
Type of cells :……………………………………………………Lithium
Power consumption (peak operation) :……………………250 W
Power consumption average :…………………………………3.6 W
(Presumed High Tx power and ping rate 1 sec.)
Environmental specifications
Operation temperature :……………………………..-5°C to +55°C
Storage temperature :………………………………-30°C to +70°C