Type MBS 1900
The pressure transmitter MBS 1900 is designed for use in air and water applications like Booster Pumps and Air Compressors. The semi-flexible pressure transmitter programme covers different output signals, absolute or gauge (relative) versions, measuring ranges from 0 – 4 bar to 0 – 25 bar and a wide range of pressure and electrical connections. Enclosure material is stainless steel AISI 316L.
Features
• Designed for use in air and water applications.
• Wetted parts of stainless steel (AISI 304).
• Pressure ranges in relative (gauge) or absolute from 0 – 25 bar.
• Output signals: 4 – 20 mA, or ratio metric.
• Absolute or relative (gauge) sensor element.
• A wide range of pressure and electrical connections.
• Digitally compensated.
Technical data
Performance (EN 60770)
| Accuracy (@ 20 °C) (incl. non-linearity, hysteresis and repeatability) | ? ± 1.0% FS |
| Non-linearity BFSL (conformity) | ? ± 0.5% FS |
| Hysteresis and repeatability | ? ± 0.1% FS |
| Total error band inside the compensated temperature range | ? ± 3.0% FS |
| Response time | < 4 ms |
| Overload pressure (Static) | 3 × FS (max. 75 bar) |
| Burst pressure | 4 × FS (max. 100 bar) |
| Durability, P : 10 – 90% FS | > 10×106 |
Electrical specifications
| Nom. output signal (short-circuit protected) |
4 ? 20 mA | Ratiometric (10 – 90% of Vsupp.) |
| Supply voltage [UB], polarity protected | 9 – 28 V | 5 V ± 10% |
| Supply – current consumption | – | ? 5 mA |
| Supply voltage dependency | ? ± 0.1% FS/10 V | ? ± 0.1% FS/10 V |
| Load [RL ] (load connected to 0 V) |
RL ? (UB-10V)/0.02A |
RL ? 5 K? @ 5 V d.c. |
| Output impedance | – | – |
Environmental conditions
| Sensor temperature range | 0 – 80 °C | ||
| Max. media temperature | 110 – (0.35 × ambient temperature) | ||
| Ambient temperature range (depending on electrical connection) | -20 – 80 °C | ||
| Compensated temperature range | 0 – 80 °C | ||
| Transport / Storage temperature range | -50 – 85 °C | ||
| EMC – Emission | EN 61000-6-3 | ||
| EMC – Immunity | EN 61000-6-2 | ||
| Insulation resistance | > 100 M? at 500 V | ||
| Vibration stability | Sinusoidal | 15 g, 5 Hz – 2 kHz | IEC 60068-2-6 |
| Random | 7.5 grms, 5 Hz – 1 kHz | IEC 60068-2-64 | |
| Shock | 200 g/1 ms | IEC 60068-2-27 | |
| Free fall | 1 m | IEC 60068-2-32 | |
| Enclosure (depending on electrical connection) | see page 4 | ||
Mechanical characteristics
| Materials | Wetted parts | EN 10088-1; 1.4301 (AISI 304) |
| Enclosure | EN 10088-1; 1.4404 (AISI 316 L) | |
| Electrical connections | see page 4 | |
| Net weight (depending on pressure connection and electrical connection) | 0.15 – 0.3 kg | |
Mounting instructions
| Width across flats | 24 mm |
| Mounting torque max | 20 Nm |
Ordering standard