The 7014 Blackwater liquid level holding tank sensor has been designed for all applications where consistently reliable and maintenance-free measurement of Black and Grey water is needed. Tank profiling software provides compensation for irregular tank shapes and multiple output options, offering compatibility for the widest range of installations.
The Blackwater holding tank sensor has a probe element which goes into the tank and is robust and tough enough to tolerate the significant forces that are caused by sloshing of the contents in rough seas. The conductive level sensor measurement is a solid-state technology that does not have any moving parts.
The sensor consists of a smooth, non-stick probe without any holes for fluid flow in it, preventing being clogged or jammed by solids that can prevent operation. The sensor’s outputs have been configured so that it can be used with existing gauges and system display screens.
Output : | Voltage Maximum 0.25-10.0V DC (configurable). |
Current 4-20mA. | |
Resistive 10-180 or 240-33 Ohms. | |
Accuracy : | +/-10% FSD @20°C |
Resolution : | 12 bit (4096 points over measurement range). |
Supply Voltage : | +6 to +32V DC |
Supply Current : | <40mA |
Operating Temperature : | -40°C to +85°C (without cable). |
Ingress Protection : | IP66/IP68/IP69k to EN60529 |
Mounting : | 1.25″ BSP Threaded |
Probe Length : | Standard 250, 350, 450, 600, 800, 1000mm. |
Custom 50 to 2000mm (MOQ applies). |
Primary Output Accuracy | +/-10% FSD @ 20°C |
Thermal Drift | <10% FSD over full temperature range |
Supply voltage | +6 to +32V DC |
Over Voltage Protection | 50V DC |
Supply Current | 15mA – 40mA (dependant on type) |
Reverse Polarity Protection | -32V DC |
Resolution | 12 bit (4096 points over measurement range) |
Output Update Rate | 100Hz (Resistive) 10Hz (0-10V & 4-20mA) |
Configuration Interface | Accessible via local micro USB port |
Primary (Volumetric) Output | Configurable through user software using tank profiling or file upload |
Secondary (Switch) Output | Open collector output 50V / 0.5A max switch to ground (V-) |
Secondary Output Hysteresis | Configurable through user software |
Primary Outputs | Simulated 10-180? or 240-33? selectable through user software |
Standard Range | Datum A to Datum B (see Dimensions) |
Primary Output Maximum Range | Simulated 10-1000? or 1000-10? Configurable through user software |
Ingress Protection | IP66 / IP68 / IP69k to EN60529 |
Operating Temperature | -40°C to +85°C (without cable) |
Humidity | 93% RH at 40°C EN60945 |
EMC | EN60945 (Marine) |
EN61000-6-3 (Light Industrial) | |
EN61000-6-2 (Heavy Industrial) | |
EN61326-2-1 (Measurement Control) | |
Corrosion Resistance | Marine grade stainless steel 316 construction |
Differential Pressure | 10 Bar |
Absolute Pressure | 5 Bar |
Compatible Media | All conductive liquids |
Venting | Use in vented tanks only |
Wetted Materials | Stainless steel 316, FEP, EPDM |
Probe Length | Range 1: 250, 350 or 450 mm |
Range 2: 600, 800 or 1000 mm | |
Range 3: Custom 50 to 2000mm (MOQ applies) | |
Tank Seal Options | EPDM O-ring or Klingersil panel gasket |
Cable | Marine standard screened cable (temperature rating -40°C to +75°C) |
Cable Pull | 3 axis, 50N |
Primary Output Standard Range | 0.25 – 4.75V DC* |
Primary Output Maximum Range | 0.25 – 10V DC* Configurable through user software |
Primary Output Standard Range | 4-20mA Range is Datum A to Datum B (see Dimensions) |
Primary Output Maximum Range | 4-20mA Configurable through user software |
Read more :
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.