STANDARD LIGHTING AND HEAT-TRACE PANELS SERIES 8146 FOR MARINE
Many different variants of R. STAHL’s lighting and heating circuit distribution systems are available; coupled with the customer-specific options on offer, these systems are incredibly versatile. Practical details enhance the safety and user-friendliness of the fuse panels, and short delivery times mean that you can have these systems up and running in next to no time.
R. STAHL Series 8118 junction boxes are equipped with 4, 5 or 8 mantle terminals depending on their design size. As an option, miniature fuses can still be installed in addition. Junction boxes are therefore also suitable for safeguarding. The robust enclosure made from glass fibre reinforced polyester resin can be equipped with plastic or metal cable glands.
- Resistant Ex e enclosure, universally usable as connection or junction boxes and/or to safeguard electric distributors up to 6.3 A
- IP66 degree of protection
- With mantle terminals or with a combination of mantle terminals and miniature fuses (optional).
Product Description : | Heating circuit distribution boards With residual current circuit breaker With overcurrent release |
Product Type : | 8146/5-ExV-05-24H16C1N-T |
Art. No. : | 137167 |
WebCode : | 8146D |
Availability | On request |
- Standard versions with short delivery times, customer-specific options possible
- With miniature circuit breaker, tripping characteristic C
- With residual current circuit breaker with overcurrent release, tripping characteristic C
- Rated currents 10, 16, 20, 25 A

TECHNICAL DATA
GENERAL
WebCode | 8146D |
Product Type | 8146/5-ExV-05-24H16C1N-T |
Product Description | Heating circuit distribution boards With residual current circuit breaker With overcurrent release |
Highlights | Standard versions with short delivery times, customer-specific options possible With miniature circuit breaker, tripping characteristic C With residual current circuit breaker with overcurrent release, tripping characteristic C Rated currents 10, 16, 20, 25 A |
Functional Description | R. STAHL Series 8146 lighting and heating panels are modular and are therefore available in a large number of standard variants which are available for rapid delivery. Customer-specific options are also possible. The circuit breakers are installed beneath a inspection window and can also be actuated from the outside, even under voltage. The switching position is visible at all times. |
EXPLOSION PROTECTION
Application range (zones) | 1, 2, 21, 22 |
IECEX gas certificate | IECEx PTB 06.0090 |
IECEx gas explosion protection | Ex db eb IIC T4 Gb |
IECEX dust certificate | IECEx PTB 06.0090 |
IECEx dust explosion protection | Ex tb IIIC T130 °C Db |
ATEX gas certificate | PTB 01 ATEX 1024 |
ATEX gas explosion protection | II 2 G Ex db eb IIC T4 Gb |
ATEX dust certificate | PTB 01 ATEX 1024 |
ATEX dust explosion protection | II 2 D Ex tb IIIC T130 °C Db |
ELECTRICAL DATA
Rated operational voltage AC | 230.00 – 400.00 V |
Rated operational current | 80 A (T4) |
Layout No. | 05 |
Frequency range | 50 – 60 Hz |
AMBIENT CONDITIONS
Ambient temperature | -20 °C … +40 °C |
MECHANICAL DATA
Degree of protection (IP) | IP66 |
Degree of protection IP (IEC 60529) | IP66 |
Enclosure material | Polyester resin, Glass fibre reinforced |
Flame retardant acc. | IEC/EN 60695, UL 94, ASTM D635 |
Max. finely stranded connection terminals | 35.00 mm² |
Width | 1578.000 mm |
Height | 684.000 mm |
Depth | 240.000 mm |
Impact strength (IEC 60079) | 7.00 J |
Enclosure colour | grey |
Weight | 95.000 kg |
Weight | 209.44 lb |
COMPONENTS
Locking device present | Yes |
Built-in unit 2 | 24 x Residual current circuit breaker 1-pole 16 A+N/30 mA/C/6 kA |
Entry 1 | 1 x 8161/7-M50-3516 |
Entry 2 | 24 x 8161/7-M25-1707 |
Entry 3 | 1 x 8161/7-M16-0902 |
Type of terminals PE 1 | 1 x Phoenix UT 2-conductor, 35 mm2, GN-YE |
Earth rail | 12 x 10 mm2 (3x)
|
A vessel was in port and the crew was loading logs on to the hatch covers. The securing system involved the use of foot wires, snatch blocks, and a wiggle wire (see image). Although it was dark, the deck was well lit by the ship’s own floodlights and the floodlights on the wharf.
The crew was wearing personal protective equipment (PPE), which included boot spikes to reduce the risk of slipping on the wet logs. The number one crane was being used to tension the wiggle wire, and two deck crew were standing close by to check the tension in the wire. The bosun was communicating with the crane operator using hand signals.
Tension was brought on the wiggle wire and then stopped at a signal from the bosun. The bosun started to walk towards the two-deck crew in preparation to attach bulldog grips to secure the tensioned wire when a foot wire directly in front of the two-deck crew suddenly parted.