Inameq

DFM Industrial flow meter

DFM Industrial is designed for accurate flow rate measurement of fuel and other liquids used in sea and river vessels, fuel delivery from truck tankers, in high-power diesel generator sets and boilers, in petrochemical, utilities and other industrial applications (IIoT).

Model line of DFM Industrial flowmeters includes autonomous counters with electronic display only (LCD) and flow meters with LCD and output interface cable for sending data to recording devices, displays, tracking units, telematics units.

DFM Industrial flowmeter is mainly used as a part of ship monitoring and machinery operation tracking systems, and as part of Industrial Internet of Things (IIoT) systems, also as autonomous solution for fuel/ liquid consumption.

Tasks

Fuel (liquid) consumption measurementFuel (liquid) consumption measurement
Machine running time trackingMachine running time tracking
Optimization of fuel (liquid) consumptionOptimization of fuel (liquid) consumption
Preventing thefts of fuel/liquid from pipelinePreventing thefts of fuel/liquid from pipeline
Engine testing for fuel consumptionEngine testing for fuel consumption

Advantages of DFM Industrial

Embedded flow computer, built-in battery, electronic display

DFM Industrial shows measured data on electronic display: 17 Counters of fuel / liquid consumption and engine/pump operating time (see the full list). Raw data is processed by embedded flow computer, which also allows to connect 2 pieces of DFM Industrial for differential liquid consumption measurement. Built-in battery provides autonomous fuel/ liquid consumption measurement even if external power supply is switched off.

Protection against tampering

DFM Industrial records special Counters for protection against tampering attempts:

  • “Interference” Counter protects DFM Industrial from magnetic field impact aimed on stopping fuel consumption measurement.
  • “Tampering” Counter registers attempts of third party to tamper flow meter data by generating artificial fuel/ liquid consumption (e.g. by blowing the air through measuring chamber).
  • “Number of Interventions” Counter keeps track of number of magnetic interference attempts.

Compliance with S6 Technology

DFM Industrial can be connected in one S6 network with fuel level sensors to provide detailed reporting on fuel/ liquid consumption. Operation parameters and Counters can also be transferred to S6-compatible display and recording units – e.g. MasterCAN Display 35, CANUp or GPS trackers/telematics units.

Fuel consumption and operating time Counters

Fuel/liquid consumption

  • Total fuel/liquid consumption, m3
  • Total fuel/liquid
  • Consumption in “Idling” mode of engine operation
  • Total fuel/liquid consumption in “Optimal” mode of engine operation
  • Total fuel/liquid consumption in “Overload” mode of engine operation
  • Total fuel/liquid consumption. Resettable
  • Instant consumption

Engine operating time

  • Total operating time, h
  • Total operating time in “Idling” engine operation mode
  • Total operating time in “Optimal” engine operation mode
  • Total operating time in “Overload” engine operation mode
  • Total operating time in “Negative” flow meter operation mode

Special

  • Engine operating time in “Tampering” mode, h
  • Engine operating time in “Interference” mode, h
  • Current engine operation mode as per fuel consumption rate
  • Fuel/liquid temperature
  • Temperature correction status
  • Correction coefficient value
  • Battery charge

DFM Industrial models

The DFM Industrial product line includes the following models:

DFM Industrial models

Model Type of output signal Connection
DFM Industrial 7 C T none thread
DFM Industrial 7 C F none flange
DFM Industrial 25 C F none flange
DFM Industrial 7 K T normalized pulse thread
DFM Industrial 7 CAN T digital, interface j1932/S6 thread
DFM Industrial 7 K F normalized pulse flange
DFM Industrial 7 CAN F digital, interface j1932/S6 flange
DFM Industrial 25 K F normalized pulse flange
DFM Industrial 25 CAN F digital, interface j1932/S6 flange

Measurement chamber characteristic

Model Nominal diameter DN, mm Nominal measuring chamber volume, l Mean time before recalibration*
DFM Industrial 25 40 1.0 60000/10
DFM Industrial 7 25 0.1 60000/10

Specification

Model DFM Industrial 7 DFM Industrial 25
MAX flow rate 7.2 ?3/h 25 ?3/h
MAX pressure 1.6  / 6.4* MPa
*on request for flange connection
1.6 / 6.4* MPa
* on request
Interface – CAN(J1939)/S6 interface
– pulse output
– autonomous (without interface)
Kinematic viscosity of liquid 0.55-300 mm2/s (cSt)
Ambient operation temperature from -20 to +60 °?
Operating principle oval gears rotation
Connection to pipeline flange, thread
Battery lifetime up to 36 months
Ingress Protection Rating IP 54 (IP67*) *?vailable on request

 