Domestic-sewage-storage-cabinet-HBNC-0.75A
This product is designed and produced in accordance with the “Statutory Inspection Rules for Domestic Navigating Sea-going Ships” (2011 Edition). The product has the characteristics of compact design, convenient and flexible installation, simple operation and convenient maintenance. In addition, this product can be installed separately according to the size of the hull space. The pump, electric control box, and pipelines are all designed to be detachable and can be installed flexibly according to actual conditions. This product integrates intelligent design, and the device is connected to the cloud. The operating data and status of the product can be read directly from the cloud. It can effectively solve the problems of artificial ranking statistics, illegal ranking, and random ranking.
| Model | Rated storage volume (m³) | Distribution power (kW) | sewage inlet | flush water inlet | vent | High overflow | exhaustion hole | Expansion port 1 | Expansion port 2 | Dimensions |
| HBNC-0.25A | 0.25 | 1 | DN150 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 650×856×650 |
| HBNC-0.25B | 0.25 | 0 | / | DN20 | DN25 | DN50 | / | DN50 | DN50 | 650×600×X650 |
| HBNC-0.35A | 0.35 | 1 | DN150 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 1000×856×600 |
| HBNC-0.35B | 0.35 | 0 | / | DN20 | DN25 | DN50 | / | DN50 | DN50 | 1000×600×600 |
| HBNC-0.5A | 0.5 | 1 | DNI50 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 800×1056×800 |
| HBNC-0.5B | 0.5 | 0 | / | DN20 | DN25 | DN50 | / | DN50 | DN50 | 800×800×800 |
| HBNC-0.75A | 0.5 | 1 | DNI50 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 1170×1056×800 |
| HBNC-0.75B | 0.5 | 0 | / | DN20 | DN25 | DN50 | / | DN50 | DN50 | 11700×800×800 |
| HBNC-1A | 1 | 1.2 | DNI50 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 1250×1056×1000 |
| HBNC-1B | 1 | 0 | / | DN20 | DN25 | DN50 | / | DN50 | DN50 | 1250×800×1000 |
| HBNC-2 | 2 | 1.2 | DN150 | DN20 | DN25 | DN50 | DN32 | DN50 | / | 1540×1256×1300 |
| HBNC-5 | 5 | 3.2 | DN150 | DN20 | DN25 | DN50 | DN40 | DN50 | / | 2100×1722×1700 |
Note:
1. Device operating environment temperature: 0~55?
2. Flushing water overflow: 2-32?:
3. Electricity system: AC 3?380V 50Hz/AC3?440V 60Hz/AC 220V 50Hz optional
4. Type B equipment only needs to be expanded on ships It can only be used when storing capacity and when at least one type A device is configured.
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.
View Comments