SC Hydraulic GBD Series Gas Booster
SC Hydraulic Engineering GB-D Series Gas Booster Single Stage Single Acting Double Head is a leading manufacturer and designer of an ever growing line of high pressure, air-driven liquid pumps, as well as air and gas boosters which are being used in a variety of industries and applications.
Growing since 1953, we offer liquid pressures as high as 65,000 psig and can exceed 17,000 psig in gas pressures.
This series has the same characteristics of the standard GB Series however the double head allows half the input pressure to achieve the same outlet pressure.
Model No. | Maximum Material Rated Gas Supply Pressure (Ps) | Maximum Material Rated Gas Outlet Pressure (Po) | A Inlet Port B Outlet Port | Static Outlet Stall Pressure | Minimum Inlet Gas Pressure (Ps) | Displacement Per Stroke (in3 per cycle) |
GB-D30 | 6,000 | 9,000 | 1/4″ NPT | 60 Pa | 200 psig (13 bar) | 3.1 |
410 bar | 620 bar | 1/4″ NPT | ||||
GB-D75 | 6,000 | 20,000 psig | 9/16″-18 (1) | 150 Pa | 250 psig (17 bar) | 1.2 |
410 bar | 1,380 bar | 9/16″-18 (1) |
(1) Coned and threaded high pressure connection for 1/4″ O.D. tubing.
(2) Maximum allowed working pressure for oxygen service boosters: 5,000-psi max.
(3) Maximum allowed working pressure for hydrogen service boosters : 6,000-psi max.
(4) Oxygen & hydrogen service boosters not available on all models. Contact factory for more information.
Refer to corresponding gas booster performance curve for operating pressures. Maximum material rated outlet pressures can be reached under special operating conditions. Do not use air drive and/or gas supply pressures that equate to higher outlet pressures than those “maximum material rated outlet pressures” shown on table. Refer to Static Outlet Stall Pressure formula shown on table (for example, for gas booster model GBD-30 the formula is: Static Outlet Stall Pressure = 30*Pa+Ps). Maximum recommended air drive operating pressure: 100-psi. Maximum rated air drive pressure: 150-psi (only for static outlet stall pressure).
TABLE 1 | Gas Booster Series (1) | ||
GB | Single Stage |
TABLE 2 | Modification | ||
Blank | No Modification | ||
M402 | Remote Pilot |
TABLE 3 | Cylinder Modification | ||
D | Double Head |
TABLE 4 | Pressure Ratio Single or First Stage | ||
15 | GB | ||
30 | GB | ||
75 | GB |
TABLE 5 | Pressure Ratio Second Stage | ||
Blank | N/A on GB-D Series |
TABLE 6 | Cylinder Modification | ||
Blank | Standard | ||
02 | Oxygen Service (2) | ||
H2 | Hydrogen Service (2) |
Notes: | (1) Do not fill gap on a two digit description (2) Not available on GBD-D75, GBT-D15/75 and GBT-D30/75 models. Contact factory for more information. |
Performance Chart
M014 – Counter Port: This option provides a 5/8-18-UNF thread port on the air motor section of the pump for installing a mechanical cycle counter. | |
M402 – Remote Pilot: This option provides a 1/8” NPT female port for remotely controlling the start/stop of the pump by connecting an external air signal to actuate the air cycling valve. |
Read more :
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.