Marine watch main alarm operator panel
The LT-ONE Main Panel has an easy to use operator interface displaying instant recognition of vessel status in the highly effective and attractive alarm management system Marine Watch LT Series.
The Marine Watch LT Series can be used in any unclassed vessel and support up to 92 I/Os with a mix of sensor types. The LT-ONE Main Panel carries 19 flexible onboard I/O out of the box, making it a super neat and cost-effective system that is quick to install.
The LT-ONE can be used stand-alone or in combination with the LT-ACE Remote Panel that visualizes alarms from up to two LT-ONE Main Panels. The LT-ACE automatically self-configures when connected to the same Ethernet network as the LT-ONE.
Size | w 167 x h 135 x d 68 mm |
Cut out | W 156 x H 124 mm, Access depth 90 mm |
Screen | Touch, 262144 colors, 5.7″, Resolution 640 x 480 pixels |
IP | IP56 |
Power Supply | 24/12 VDC, Min 8 VDC, Max 32 VDC |
Part#: 1006475 (DCU 210E Engine Controller)
1500074 (Marine Watch LT)
Section | Qty. | Min | Typ. | Max | Unit | Comment |
Power Supply, Voc | 1 | 8 | 12/24 | 32 | VDC | Current consumption @ 24 VDC |
– | 0.5 | 2 | A | |||
Flexible I/O | 19 | 0 | – | Can be configured as described in section Flexible I/O section below. | ||
Relay | 2 | 0 | – | 1 | A | Potential free/Form C contacts. Internally fused |
Tacho | 1 | 0.1 | 5 | 10 | kHz | Magnetic pickup |
4 | – | 32 | Vpp | |||
Thermistor/PT100 Inpt | 2 | 50 | – | 60000 | ? | Accuracy: ± 2.0 %. With optional wire resistance comp. |
0 | – | 800 | °C | |||
CAN bus #1 | 1 | – | 250 | – | kbps | SAE J1939 |
CAN bus #2 | 1 | – | 250 | – | kbps | SAE J1939 |
Ethernet | 1 | – | 10/100 | – | Mbps | Auto Crossover |
Modbus TCP | 1 | – | 10/100 | – | Mbps | |
Modbus RTU | 1 | 9600 | 19200 | 115200 | baud | 8 bit, even parity, 1 stop bit. Failsafe biasing, internal termination |
RIO Link Connection | 1 | – | 19200 | – | baud | 8 bit, even parity, 1 stop bit |
USB Port | 1 | – | – | 480 | Mbps | USB 2.0 Hi-speed Memory Interface |
Section | Qty. | Min | Typ. | Max | Unit | Comment |
Digital Input | 19 | 8 | – | 36 | V | High level Low level |
0 | – | 2 | V | |||
4 – 20 mA Input | 19 | 0 | 4-20 | 25 | mA | Accuracy: ± 0.5 % of typical range |
Analogue Input | 19 | 0 | – | 32 | V | Accuracy: ± 0.05 V |
Digital Output | 19 | – | Vcc-0.5 | – | V | Power supply – 0.5 V Current limited |
0 | – | 0.2 | A | |||
0 V Supply Output | 4 | 0 | 0.1 | – | V | |
0 | – | 0.5 | A | |||
5 V Supply Output | 1 | 4.8 | 5.0 | 5.2 | V | For supply of 0-5 V sensors etc. Current limited |
0 | – | 0.1 | A |
Section | Width | Typ | Height | Unit | Comment |
Size | – | 5.7 | – | inch | |
Resolution | 640 | – | 480 | pixels | |
Pixel Density | 1400 | PPI | |||
Colours | – | 262144 | – | colours |
Part#:
1006475 (DCU 210E Engine Controller)
1500074 (Marine Watch LT)
Operator Interface
? Capacitive touch interface
? Touch buttons
? Part# 1006475: 4 buttons
? Part# 1500074: 2 buttons
Connectors
? 4 x 12 pin Deutsch DT06-12SA (Mating connector).
? USB 2.0 Type A Host Port (Service only).
? Ethernet RJ45 IP67 Bajonett Black (Use included RJ45 Plug Kit).
Section | Weight | Width | Height | Depth | Unit | Comment |
Size | – | 167 | 135 | 68 | mm | Depth without connectors |
Cut out | – | 156 | 124 | – | mm | Access depth: 90 mm |
Weight | 0.8 | – | – | – | kg |
Section | Condition | Min. | Typ. | Max. | Unit | Comment |
Operating Temperature | Operational | -25 | – | +70 | °C | DNV No. 2.4 Location Class D, Open deck |
Storage Temperature | Not power | -30 | – | +85 | °C | |
Enclosure Ingress Protection Rating | Operational | IP56 | – | – | – | |
Vibration | Operational | – | 4 | – | g | IEC 60068-2-6 Fc |
Tested according to DNV Standard for Certification DNV No. 2.4, harmonized with IACS UR E10 and IEC 60092-504.
Read more :
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.
View Comments