Rheonik RHE14
The RHE14 is a low cost mass flow transmitter ideal for OEM and embedded system use. The RHE14 is DIN rail mount and configured through a native RS232 data port. The RHE14 can be used with all RHM Coriolis Sensors.
| MEASUREMENTS | Mass Flow Temperature |
| OUTPUTS | 1 Analog |
| 1 Pulse / Frequency | |
| 2 Digital | |
| INPUTS | 1 Remote Zero |
| INTERFACES | RS 232 HART |
Applications
- Filling and dispensing
- Liquid and gas applications
- Feed stocks and transfers
General Specifications
| Housing: | DIN rail mounting enclosure (polycarbonate (PC) and polyphenylene oxide (PPO)) |
| Enclosure Rating: | IP 20 |
| Ambient Temperature: | -40°C to +65°C (-40°F to +149°F) |
| Dimensions: | 70 x 86 x 58 mm (2.76 x 3.39 x 2.28 in) |
| Operation: | Via serial port using SensCom PC software |
| Sensor Cable Connection: | Screw terminals |
| Analog Outputs: | 1 active 4-20 mA output, configurable for mass flow or temperature |
| Pulse Outputs: |
2 outputs, one active (TTL, IOHmax = -0.4 mA, IOLmax = 8 mA), one passive(opto-isolated open collector type, Fmax = 10 kHz, Umax = 24 V, Imax= 10mA(requires external power supply and site installed current limiting/pull up resistor))operating in tandem
|
| Digital Outputs: |
2 digital outputs individually configurable as either active or passive(requires external power supply and site installed current limiting/pull up resistors) for error and flow direction
|
| Digital Inputs: | 1 input for remote zero |
| Power Supply: | 8 – 28 VDC +/- 10% |
| Digital Data Communications: | RS232 with either HART or Rheonik simple ASCII protocol |
| Weight: | 0.2 kg (0.44 lb) |
Read More :