The working principle is a capacitive measurement operating on absorption of water in oil. The physical measured value is % Humidity. New oil has the ability to hold a certain amount of dissolved water. The maximum water amount oil can hold is called “saturation point”. Above the “saturation point” free water will fall out which can cause corrosion inside of the engine. The “saturation point” is influenced by temperature and other different factors like the composition of oil mineral or synthetic, formulation of additives and will change during the lifetime of the oil. The Water in Oil Sensor (WiO) is not measuring free water or emulsion, which is detectable by regular Water in Oil test kits, it measures the absolute water content in oil.
The PAV (Pre Alarm Value) is set to 50% humidity. The MAV (Main Alarm Value) is set to 90% humidity.
More than 100% humidity means free water is present. From this point regular Water in Oil test kits begin to measure.
Normally in the field, the water in oil content is measured by a Water in Oil test kit. The results are mostly <0.02% (or 100.02% humidity), this value means free water content. If the WiO Sensor shows the main alarm, the value is higher than 90% humidity and damage could be caused to the engine if 100% humidity is reached.
| MEASUREMENT | |
| Power Supply | 18…32 VDC |
| Current Consumption | 60mA |
| Polarity Protection | Yes |
| Alarm relays | Pre-alarm at 50% humidity Main alarm at 90% humidity |
| Output Current | <300mA |
| Operating Temperature | -25 to +85 0C |
| Protection Degree | IP67 |
| Analog Output: Water in Oil | 4…20 mA (equiv. 0…100% Humidity Linear) |
| Analog Output: Temperature | 4…20 mA (equiv. 0…1000C Linear) |
| Dimensions: | 125mm x 80mm x 57mm |
| Local Indication | LED Indicators |
| Sensor Probe Specification | |
| Wrong Polarity Protection | Yes |
| Operating temperature | -25 to 85 0C |
| Protection degree | IP65 |
| Pressure resistance against medium | 10 bar |
| Connection type | G3/4” Male Thread |
| Material | Stainless Steel AISI 303; 1.4305 |
| Dimensions | 50mm x 187mm |
| Cable Length to Controller | 15m |
| Insertion Length | 120mm |
| Local indication | LED Indicators |
| Options | |||
| Indicator Dial Temperature | Indicator Dial Humidity | ||
| Indicator Dial type | Analog needle type | Indicator Dial type | Analog needle type |
| Unit of Measurement | Degrees Celsius | Unit of Measurement | % Humidity |
| Range | 0 – 1000C | Range | 0% – 100% Humidity |
| Dimensions | 96mm x 96mm x 77mm | Dimensions | 96mm x 96mm x 77mm |
Specifications and system descriptions accurate at time of printing. These are subject to change.
Read more
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.