It may happen that all the provision rooms or cargo holds are maintained at correct temperature, but in doing so the discharge temperature of the compressor is going above the limit. This problem may arise due to following reasons :
Reasons | Solutions |
Excessive suction temperature due to less refrigerant in the circuit. | Recharge the circuit to maintain refrigerant quantity in the circuit. Ensure TEV is set properly and supplying enough to the evaporator, else degree of superheat will result in increase of suction and discharge temperatures of the compressor. |
Leak in the discharge valve leads to generation of heat. | Renew the leaky valve. |
Leak in the safety valve. | Renew safety valve. |
Open bypass between suction and discharge. | Control the bypass to avoid this. |
The objective of any refrigeration system is to collect heat from a low temperature area and move it to a high temperature area. Refrigerant is a substance that acts as a cooling agent by absorbing and giving off heat. Usually there are two types of refrigeration systems commonly encountered : namely the vapor compression cycle refrigeration system and the vapor absorption cycle refrigeration system. The most common system that is used on all ships is the vapor compression cycle refrigeration system.
Onboard ship refrigeration systems are used in the carriage of some liquefied gases and bulk chemicals, air conditioning for accommodations, to cool the bulk carbon dioxide for firefighting systems, to preserve perishable foodstuff during storage, and to preserve stores on ships like fish, meat, vegetables, and dairy products. It is required to maintain the temperature of the above items within desired limits throughout the voyage, so the refrigeration system will be running throughout the voyage which may lead to various problems during its operation. In this article let us see how to identify various faults in refrigeration systems, the causes for the faults, and the actions to be taken to troubleshoot those problems in refrigeration systems. Faults like under charging, over charging, air in the system, moisture in the system, and oil in the system will be discussed in this article.
Indication :
Causes :
Expansion valve may be blocked at the strainer Partial blockage of refrigerant at the filter or drier or evaporator may cause undercharging.
Action :
Indication :
The liquid level in the condenser is too high (high condenser gauge reading). This will reduce the available condensing surface, with corresponding increase in the saturation temperature and pressure.
Causes :
Action :
This normally comes with the ingress of air in the system. Moisture may freeze at the expansion valve, giving some of the indication of under charging. It will contribute to the corrosion in the system. It may cause lubrication problems and breakdown of the lubricating oil in the refrigerant compressor.
Action:
Indication :
This may cause the refrigeration compressor to overheat, with a high discharge pressure and normal condensing temperature.
If there is excessive air, it may reduce the cooling capacity of the system, making the compressor to run for the extended period of time.
Causes :
Action :
Air in the system can be removed by collecting the system gas in the condenser, leaving the condenser cooling water on and venting out the air from the top of the condenser because air will not be condensed in the condenser but remains on top of the condenser above the liquid refrigerant.
Connect the collecting cylinder to the purging line of the condenser, open the valve, and collect air in the cylinder.
Indication :
Temperature is not dropping in the cold rooms as normal, due to fact that oil act as insulation in the evaporator.
Causes :
Oil may carry over from the compressor and may not come back to the compressor due to blockage in the system.
Defective piston rings or worn out liner of the compressor may cause the oil to carry over along with the refrigerant.
Action:
If there is oil in the cooling coils, increase the condenser and evaporator temperature differentials and remove excess frost on the suction pipe.
This is seen as liquid getting back to the suction of the refrigerant compressor. It may be due to a faulty or incorrectly adjusted expansion valve and also due to solenoid valve leakage. It may also result from overcharging of the refrigeration system. Flooding may lead to an iced up evaporator.
Read more :
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.
View Comments