The K-Bridge sensor integrator is used for data collection and distribution of navigation sensor information to subsystems interconnected using KONGSBERG system technology.
K-Bridge sensor integrator makes individual cabling from sensors to each subsystem unnecessary. Upgrades and extensions to the overall system can take place without rewiring to sensors. Multiple K-Bridge SINT units may be installed to segregate groups of sensors for the highest availability.
The equipment is designed to conform to the following standards :
The K-Bridge BNWAS is a type-approved alarm system for ensuring that the bridge of a vessel is constantly manned.
The K-Bridge Bridge Navigational Watch Alarm System is part of the K-Bridge integrated navigation system from Kongsberg Maritime.
It is designed to monitor bridge activity and alert the ship’s captain and/or other qualified navigators if the bridge becomes unattended.
If there has been no activity on the bridge for a specified time period of between 3 and 12 minutes, the alarm is raised in the following four stages :
1. A pre-warning lamp is lit on the bridge.
2. After 15 seconds, if nothing happens to reset the timer, a buzzer sounds on the bridge.
3. After another 15 seconds, if nothing happens to reset the timer, buzzers sound in selected backup navigators’ cabins.
4. 90 seconds after the buzzers sound in the backup navigators’ cabins, if the ALARM RESET button has not been pressed, buzzers sound in the common areas of the crew’s accommodation.
Since the Central Alarm System (CAS) and the BNWAS are both integrated features of the K-Bridge Navigation System, any alarm from the radar or sensors that is not acknowledged within 30 seconds will trigger the BNWAS alarm sequence.
| Component | Mininum | Maximum |
| Main reset panel | 1 | 1 |
| Pre-warning reset panel | 0 | 6 |
| Motion detectors | 0 | 4 |
| Cabin buzzers | 2** | 5*** |
| Bridge buzzer | 1 | 1 |
* This table lists the components required for the forward bridge; additional components will be required for the aft bridge.
** There must be a minimum of one buzzer in the captain’s cabin and one in the common area of the crew’s accommodation.
*** Five independent selectable channels are available (on the SINT) for cabin buzzers. If more than five cabin buzzers are required, more than one buzzer can be connected to each channel.
The K-Bridge BNWAS is approved in accordance with EU MED 96/98/EC A.1/4.57 as a Bridge Navigational Watch Alarm System.
Read more :
Rheonik Fuel Consumption For Marine Application, Rheonik Coriolis mass flow meters have been used for…
Coriolis Mass Flow Meters For Marine Fuel Consumption Application, Rheonik Coriolis mass flow meters have…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
In commercial shipping, now more than ever, fuel consumption measurements are an important part of…
Mengukur konsumsi bahan bakar di sebuah mesin atau engine, disini kita melihat penjelasan bagaimana bahan…
Mengukur Konsumsi Bahan Bakar di Kapal Dengan Fluidwell Tipe F127 Mengukur konsumsi bahan bakar di…
This website uses cookies.
View Comments