The K-Bridge sensor integrator is used for data collection and distribution of navigation sensor information to subsystems interconnected using KONGSBERG system technology.
K-Bridge sensor integrator makes individual cabling from sensors to each subsystem unnecessary. Upgrades and extensions to the overall system can take place without rewiring to sensors. Multiple K-Bridge SINT units may be installed to segregate groups of sensors for the highest availability.
The equipment is designed to conform to the following standards :
The K-Bridge BNWAS is a type-approved alarm system for ensuring that the bridge of a vessel is constantly manned.
The K-Bridge Bridge Navigational Watch Alarm System is part of the K-Bridge integrated navigation system from Kongsberg Maritime.
It is designed to monitor bridge activity and alert the ship’s captain and/or other qualified navigators if the bridge becomes unattended.
If there has been no activity on the bridge for a specified time period of between 3 and 12 minutes, the alarm is raised in the following four stages :
1. A pre-warning lamp is lit on the bridge.
2. After 15 seconds, if nothing happens to reset the timer, a buzzer sounds on the bridge.
3. After another 15 seconds, if nothing happens to reset the timer, buzzers sound in selected backup navigators’ cabins.
4. 90 seconds after the buzzers sound in the backup navigators’ cabins, if the ALARM RESET button has not been pressed, buzzers sound in the common areas of the crew’s accommodation.
Since the Central Alarm System (CAS) and the BNWAS are both integrated features of the K-Bridge Navigation System, any alarm from the radar or sensors that is not acknowledged within 30 seconds will trigger the BNWAS alarm sequence.
| Component | Mininum | Maximum |
| Main reset panel | 1 | 1 |
| Pre-warning reset panel | 0 | 6 |
| Motion detectors | 0 | 4 |
| Cabin buzzers | 2** | 5*** |
| Bridge buzzer | 1 | 1 |
* This table lists the components required for the forward bridge; additional components will be required for the aft bridge.
** There must be a minimum of one buzzer in the captain’s cabin and one in the common area of the crew’s accommodation.
*** Five independent selectable channels are available (on the SINT) for cabin buzzers. If more than five cabin buzzers are required, more than one buzzer can be connected to each channel.
The K-Bridge BNWAS is approved in accordance with EU MED 96/98/EC A.1/4.57 as a Bridge Navigational Watch Alarm System.
Read more :
Wireless position sensor GNOM DP S7 is used in transport telematics systems (GPS/GLONASS vehicle monitoring…
Pressure sensor GNOM DDE is used to determine the axle load in vehicles equipped with…
Axle Load Sensor GNOM DP Technoton position sensor is designed for measuring axle and cargo…
FMSCrocodile is used within for vehicle telematics system as a ready-made solution for safe integration…
Contactless J1708 Reader Technoton is designed for safe data reading from J1708 bus (SAE J1587)…
CANCrocoLITE Technoton — is a tool for Telematics systems used for data reading from on-board…
This website uses cookies.
View Comments