Regulation device for pump control equipped with flow and pressure sensor connected to an electronic system. Inlet and delivery connection ports of the same diameter. Built-in check valve. Pressure gauge 0-12 bar supplied as standard for IDROMAT 5. Automatic reset function for the reset of the system without manual operation.
Applications
Automatic control of pumps for water supply and increase of network pressure. Control of starting/stopping of the pump when cocks are opened/closed.
For protection of the pump :
Operating conditions
Mains voltage : Single-phase 230 V ±10% Idromat 5e;
Frequency : 50 – 60 Hz.
Current values: 8A max during operation (16A max at start-up).
Maximum pump motor power 1,5 kW.
Protection : IP 65.
Maximum working pressure : 12 bar (1,2 MPa)
Maximum Operating temperature up to 65 °C.
Minimum flow ~ 1 l/min.
Male connections 1” .
TYPE | Switching-on pressure | Pump head |
IDROMAT 5-12 | 1,2 bar | > 20 m |
IDROMAT 5-15 | 1,5 bar | > 23 m |
IDROMAT 5-22 | 2,2 bar | > 30 m |
IDROMAT 5-30 | 3 bar | > 40 m |
IDROMAT 6-15 | 1.5 bar | > 23 m |
IDROMAT 6-30 | 3 bar | > 40 m |
IDROMAT 5e | adjustable from 1,5 to 2,5 bar |
Materials
Component : IDROMAT 5-5e
Housing : Polyamide PA 6 G.F. reinforced
Membrane : Natural rubber
Comparison of pressure values
Domestic Sewage Treatment Device HBNB-20 For Marine, in response to the increasingly stringent environmental requirements,…
Domestic Sewage Storage Cabinet HBNC-0.75A For Marine, this product is designed and produced in accordance…
Domestic Sewage Treatment Device HBNB-15 For Marine, Domestic Sewage Treatment Device HBNB-15 For Marine, In…
Domestic Sewage Treatment Device HBNB-20 For Marine, In response to the increasingly stringent environmental requirements,…
Domestic Sewage Treatment Device HBNB-10 For Marine, In response to the increasingly stringent environmental requirements,…
Domestic Sewage Treatment Device HBNA-20 (Double Pump) For Marine, HBNA series domestic sewage treatment equipment…
This website uses cookies.