Orbis Marine conventional fire detectors offer a wealth of features to save time, enhance reliability and reduce false alarms within the marine environment. These include drift compensation and DirtAlert®, a feature that warns Service Engineers via a flashing yellow LED that detectors need maintenance; and patented FasTest®, a procedure that takes just four seconds to test smoke detectors and confirm that they are functioning correctly.
Approved for use in marine environments Modern, low-profile design TimeSaver® Base for fast installation Transient rejection for false alarm reduction High humidity tolerance at up to 98% RH Wide operating temperature -40°C to +70°C
Orbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit – the alarm level – has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.
Heat detectors have a wide range of response characteristics and the choice of the right type for a particular application may not always seem straightforward. It is helpful to understand the way that heat detectors are classified as explained earlier and to memorize a simple rule: use the most sensitive heat detector available consistent with avoiding false alarms. In the case of heat detectors it may be necessary to take an heuristic approach, ie, trial and error, until the best solution for a particular site has been found. The flowchart (refer to datasheet PP2479) will assist in choosing the right class of heat detector. If the fire detection system is being designed to comply with BS 5839–1: 2002 heat detectors should be installed at heights of less than 12 meters with the exception of class A1 detectors, which can be installed at heights up to 13.5 meters.
The Orbis range incorporates seven heat detector classes to suit a wide variety of operating conditions in which smoke detectors are unsuitable. The European standard EN54-5:2001 classifies heat detectors according to the highest ambient temperature in which they can safely be used without risk of false alarm. The classes are identified by the letters A to G. (Class A is subdivided into A1 and A2.) In addition to the basic classification, detectors may be identified by a suffix to show that they are rate-of-rise (suffix R) or fixed temperature (suffix S) types. All heat detectors in the Orbis range are tested as static or rate-of-rise detectors and are classified as A1R, A1S, A2S, BR, BS, CR and CS.
The environmental performance is similar to that of the Orbis optical smoke detector but it should be noted that heat detectors are designed to work at particular ambient temperatures (refer to Specialist Environments Product Catalgue PP2479).
The Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.
General | |
Applications |
|
Warranty | 10 year |
Performance | |
---|---|
Chamber Type | Chevron |
Heat Classification | A1R |
Electrical | |
Maximum Power-Up Time | <20 seconds |
Quiescent Current | 95μA |
Quiescent Current Tested At | 24V dc |
Sampling Frequency | Once every 4 seconds |
Polarity | L1 & L2 are polarity sensitive |
Minimum ‘Detector Active’ Voltage | 6V |
Alarm Current (At 12 Volts) | 20mA |
Alarm Current (At 24 Volts) | 40mA |
Holding Voltage (Min) | 5V |
Holding Voltage (Max) | 33V |
Holding Voltage | 5 to 33V |
Minimum Voltage To Light Alarm LED | 5V |
Alarm Reset Voltage | <1V |
Alarm Reset Time | 1s |
Alarm Load | 600Ω |
Environmental | |
Humidity (Min) | 0% RH |
Humidity (Max) | 98% RH |
Humidity Note | no condensation or icing |
Humidity | 0% to 98% (no condensation or icing) |
IP Rating Value | IP23D |
Conformance | |
Approvals |
|
Mechanical | |
Weight | 70g |
Colour | White |
Materials Housing | Polycarbonate |
Product Length | 36mm |
Product Diameter | 97mm |
Domestic Sewage Treatment Device HBNB-20 For Marine, in response to the increasingly stringent environmental requirements,…
Domestic Sewage Storage Cabinet HBNC-0.75A For Marine, this product is designed and produced in accordance…
Domestic Sewage Treatment Device HBNB-15 For Marine, Domestic Sewage Treatment Device HBNB-15 For Marine, In…
Domestic Sewage Treatment Device HBNB-20 For Marine, In response to the increasingly stringent environmental requirements,…
Domestic Sewage Treatment Device HBNB-10 For Marine, In response to the increasingly stringent environmental requirements,…
Domestic Sewage Treatment Device HBNA-20 (Double Pump) For Marine, HBNA series domestic sewage treatment equipment…
This website uses cookies.