SUMMARY
The Gill liquid level sensor is a lightweight, solid-state capacitive liquid level sensor available in an almost unlimited combination of length and mounting arrangements, all delivered in short lead times. It is compatible with a wide range of liquids and is able to operate in high temperatures.
The sensor is a form fit and function replacement for the R-Series sensors as well as bringing the flexibility to be adapted to a broad range of mechanical mounting configurations. Standard stock adaptors are available for 1, 2, 3 & 5 bolt mounting as well as metric and imperial male thread designs.
Used across motorsport, industrial and defence industries, the 4223 Lightweight Level Sensor has proven reliability in punishing environments.
FLEXIBLE MOUNTING OPTIONS
For real product flexibility, you have the ability to design your own custom configurations to suit any flat gasket seal configuration, limitless thread adaptions to both Male and Female threads.
To order, simply tell us your probe length requirements and you Fuel/Oil/Water or Coolant type for calibration and we produce a fully sealed and ready to use sensor. You can then choose one of our off-the-shelf adaptors or request the CAD data to produce a customised adaptor of your own.
FEATURES AND BENEFITS
- Suitable with fuels, oils, coolants.
- Multiple mounting flange options.
- Lightweight aluminium construction.

TECHNICAL
Output : | Primary; Output Voltage 0.25-10V DC Secondary; Output Open Collector 50V/1a max switch to ground (V-) |
Accuracy : | ±1% @ 50% FSD (full scale deflection) @ 20?C |
Resolution : | 10 bit (1024 points over measurement range) |
Supply Voltage : | +5 to +32V DC |
Supply Current : | <20mA |
Ingress Protection : | IP68 |
Mounting : | 1, 2, 3, 5 hole & M22x1.5 flanges |
Length : | 100 to 750mm |
Lightweight, adaptable liquid level measurement.

- Compatible with fuels, oil, and coolants.
- Multiple standard and custom mounting options.
- Aluminium construction with side or top cable exits.
- -40°C to +125°C temperature range.
- Tank volume output.
- Temperature output option.
- High or low switch output option.
OUTPUT
Primary output standard range | 0.25 – 4.75V Range is Datum A to Datum B (see drawing overleaf) |
Primary output maximum range | 0.25 – 10V (configurable through user software. |
Primary output accuracy | ±1% @ 50% FSD (full scale deflection) 20°C |
Primary volumetric output | Configurable through user software. Tank profiling Wizard or CSV file upload |
Secondary output (option N) | Open collector output 50V / 1a max switch to ground (V-) |
Secondary output hysteresis (option N) | Configurable through user software. |
Secondary output (option Y) | 0.25 – 4.75V. (0.25V = -40°C, 4.75V = +125°C) (not configurable through GSlevel) |
Secondary output accuracy (option Y) | +/-1.5°C between 0°C and +125°C |
+/-2.0°C between -40°C and 0°C |
ELECTRICAL
Supply voltage | 5-32VDC |
Supply current | <20mA |
Interface | Compatible with RS232 |
Resolution | 10 bit (1024 points over measurement range) |
Sample rate | 100Hz |
WIRING
Cable | Flying lead, 1000mm |
Number of cores | 6 with drain wire |
Wire size | 26AWG 7/0.15 |
Sleeving | XLPE |
ENVIRONMENTAL
Ingress Protection | IP68 |
Shock tested to | BS EN 60068-2-27 (half-sine pulse 25g, 6ms 1000 shocks (positive and negative) in each 3 axis) |
Vibration tested to | Resonant frequency search 5 to 2500Hz @ 0.5g peak |
Pressure | 10 bar (absolute and differential) |
Drop | 1m (in packaging) on all 3 sides |
Thermal shock | to BS EN 60068-2-14, test Na |
Dry heat | to BS EN 60068-2-2, test Bb |
Cold | to BS EN 60068-2-1, test Ab |
Damp heat | to BS EN 60068-2-30, test Db |
EMC immunity | BS EN 60945, BS EN 61326 and BS EN 61000-6-1/2/3/4 |
MECHANICAL
Lengths available | 100-750mm in 1mm steps |
Mounting options | 1 hole, 2 hole, 3 hole, 5 hole and M22x1.5 threaded |
Sealing options | Panel gasket or o-ring |
Cable exit options | Top or Side |
Weight | 36.5 g (100mm probe with 1000mm cable |
+0.34g per additional mm (probe) |
LIQUIDS
Fuels | Diesel, Gasoline, Biofuels |
Oils | Hydraulic, Gear, Motor, Vegetable, Synthetic Ester, Polyalphaolefin, Polyglycol |
Coolants | Ethylene Glycol, Water |
Other | Salt water |